Quality Control

Water, power surges and weak components cause most outdoor light failures. We check for each of them before shipment.

Our Test Lab

The factory lab tests the four things that decide how long an outdoor light lasts: light output, sealing, heat and the driver.

Photometric test

Photometric test

An integrating sphere measures luminous flux, efficacy, color temperature and color rendering. Ask us for the photometric data of your model.

Waterproof test

Waterproof test

A spray chamber checks the seals of housings and cable glands. Water is the most common reason outdoor lights fail.

High and low temperature test

High and low temperature test

A climate chamber runs lights through hot and cold cycles, the conditions a driver meets on a desert site or in a northern winter.

Electrical test

Electrical test

The test bench checks driver output, power factor and insulation, so a weak driver stays in the factory.

Our Quality Checks

  1. 1

    Batch traceability

    Each light belongs to a recorded production batch. If a light fails on site, we trace the batch to find the cause.

  2. 2

    Sealing

    Housings are die-cast aluminum with a sealed optical chamber. Our outdoor series carry an IP66 rating.

  3. 3

    Surge and voltage

    Our quotation states the input voltage range and surge level of each item, from 4 kV on small economy lights to 10 kV on HILE and HILO. Any series can be upgraded to 10 kV.

  4. 4

    Aging test

    We power on and age each finished light before packing, so early failures show up at the factory.

  5. 5

    Pre-shipment inspection

    You can send your own inspector or a third-party agency to check the goods before loading.

If a light still fails in use, our warranty terms explain how to report it and how we replace it.

Stock and Packing

Housings and parts wait on the shelves, and the carton store keeps export boxes ready for packing.

Housings and parts in our warehouseCarton store for export packing

Certificates

Our AMOS flood light series is tested by TÜV SÜD to the IEC and EN luminaire safety and EMC standards. The certificates are issued to our partner factory. We send the full PDF files with your quotation, and test reports for other series on request.

  • CB Test Certificate SG PSB-LE-06662, issued by TÜV SÜD PSB, Singapore

    CB Test Certificate

    IECEE CB Scheme, luminaire safety

    No.
    SG PSB-LE-06662
    Issued by
    TÜV SÜD PSB, Singapore
    Standards
    IEC 60598-1, IEC 60598-2-5
    Models
    AMOS 30W to 400W
    Date
    2025-05-09
  • Attestation of Conformity, LVD N8A 128461 0003, issued by TÜV SÜD Product Service, Germany

    Attestation of Conformity, LVD

    EU Low Voltage Directive 2014/35/EU

    No.
    N8A 128461 0003
    Issued by
    TÜV SÜD Product Service, Germany
    Standards
    EN IEC 60598-1, EN 60598-2-5, EN 62493
    Models
    AMOS 30W to 400W
    Date
    2025-05-12
  • Attestation of Conformity, EMC E8A 128461 0001, issued by TÜV SÜD Product Service, Germany

    Attestation of Conformity, EMC

    EU EMC Directive 2014/30/EU

    No.
    E8A 128461 0001
    Issued by
    TÜV SÜD Product Service, Germany
    Standards
    EN IEC 55015, EN IEC 61547, EN IEC 61000-3-2, EN 61000-3-3
    Models
    AMOS 30W to 400W
    Date
    2024-10-14
  • Attestation of Conformity, UK N8AUK 128461 0004, issued by TÜV SÜD, China

    Attestation of Conformity, UK

    UK Electrical Equipment (Safety) Regulations 2016

    No.
    N8AUK 128461 0004
    Issued by
    TÜV SÜD, China
    Standards
    EN IEC 60598-1, EN 60598-2-5, EN 62493
    Models
    AMOS 30W to 400W
    Date
    2025-05-12